1-866-935-6764

Rental Units, Dormitories, Assisted Living Facilities, Senior Housing, Recovery Centers

heat kills bugs

All of these housing types carry an increased risk of bed bug infestation due to the sometimes transitory nature of their residents.

THERMOCLAVE Heater Packages are:

  • Cost Saving - heaters maintain a constant discharge air temperature resulting in reduced operating costs

  • Faster - constant discharge air temperature also results in shorter treatment times, 4 - 6 hour average for 200 - 300 square feet*

  • Easy - to set up and use

  • Discrete - fewer pieces of equipment to treat a defined space

Heat is a proven method for killing bed bugs. With a THERMOCLAVE Heater Package, you can utilize your maintenance staff to execute heat treatments the moment a bed bug problem is identified. Maximum effectiveness can be achieved when heat treatments are combined with a preventative natural residual control program done in-house or offered by a Pest Control Professional.

We offer the standard packages described below but realize that property managers are often in charge of a wide range of property types and sizes. If the packages shown below don't appear to fit your individual situation -- Call Us! We'll listen and work with you to put together the right equipment that best suits treating all of your properties.

* Treatment times vary depending on cubic footage, construction type, initial ambient temperature, and items contained in a space.

THERMOCLAVE LTM 9 Package

THERMOCLAVE LTM 9 Package

Ideal for treatment areas up to 300 sq. ft. - hotel rooms, motel rooms, dorm rooms, self-storage units, pods, and larger vehicles such as transit buses and larger panel trucks.

killing bed bugs with high heat
  • 1 - THERMOCLAVE LTM 9 Electric Heater

  • 1 - 50' 8/3 50A Extension Cable

  • 2 - 16" 3,000 CFM 120V Hi Temp Transmitter

  • 1 - Wireless Temperature Transmitter
  • Heat controlled by a solid state relay.
  • Thermal overload protection.
  • High-quality tube axial fan with ball bearings for lowest noise and longest life.
  • Corrosion resistant, galvanized steel enclosure.
  • Discharge air duct.
  • NEMA style 6 - 50P Plug.
  • Dual discharge air temperature 125° F / 155° F set point.
  • Built-in electronic temperature controller and sensor proportionally modulates the heating load to match the exact capacity required for energy efficient operation.
  • Temperature sensor controls the heater proportionally to maintain the pre-set air discharge temperature.
  • Open coil elements made of the highest grade nickel-chrome resistance wire will not age or oxidize, thus assuring longer heater life.

Heater Specifications:

Capacity Max
Output (BTU/Hr)
Max Temperature Output Max
Air Flow (CFM)
Voltage AMP Rating Overall
Dimensions
(L x W x H)
Weight
(lbs.)
9 kW 30,717 155° F 300 208/240V
Single Phase*
37.5 28.5" x 15" x 16.75"
(incl. 1.75" handles)
54
bed bugs*Three Power Circuit model also available.

Fan Specifications:

Air Flow (CFM) Speed (RPM) Voltage Noise Level (dB) Dimensions
(L x W x H)
3,000 - 3,250 1,160 120V 50 21.3" x 20.7" x 18.1"

THERMOCLAVE LTM 9 Stand-alone

THERMOCLAVE LTM 9

Ideal for treatment areas up to 300 sq. ft. - hotel rooms, motel rooms, dorm rooms, self-storage units, pods, and larger vehicles such as transit buses and larger panel trucks.

  • Heat controlled by a solid state relay.LTM9 Heater kills bed bugs
  • Thermal overload protection.
  • High-quality tube axial fan with ball bearings for lowest noise and longest life.
  • Corrosion resistant, galvanized steel enclosure.
  • Discharge air duct.
  • NEMA style 6 - 50P Plug.
  • Dual discharge air temperature 125° F / 155° F set point.
  • Built-in electronic temperature controller and sensor proportionally modulates the heating load to match the exact capacity required for energy efficient operation.
  • Temperature sensor controls the heater proportionally to maintain the pre-set air discharge temperature.
  • Open coil elements made of the highest grade nickel-chrome resistance wire will not age or oxidize, thus assuring longer heater life.

Heater Specifications:

Capacity Maximum Output (BTU/Hr) Maximum Temperature Output Maximum Air Flow (CFM) Voltage AMP Rating Overall Dimensions
(L x W x H)
Weight
(lbs.)
9 kW 30,717 155° F 300 208/240V
Single Phase*
37.5 28.5" x 15" x 16.75"
(incl. 1.75" handles)
54
bed bugs*Three Power Circuit model also available.

THERMOCLAVE LTM 20

THERMOCLAVE LTM 20

Ideal for treatment areas up to 400 - 600 sq. ft. - residential spaces, small commercial spaces, larger hotel rooms and motel rooms.

    high heat kills bed bugs
  • Heat controlled by a solid state relay.
  • Thermal overload protection.
  • High quality tube axial fan with ball bearings for lowest noise and longest life.
  • Corrosion resistant galvanized steel enclosure.
  • 50 amp twist lock electrical connection.
  • Dual discharge air temperature 125° F / 155° F set point.
  • Built-in electronic temperature controller and sensor proportionally modulates the heating load to match the exact capacity required for energy efficient operation.
  • Temperature sensor controls the heater proportionally to maintain the pre-set air discharge temperature.
  • Open coil elements made of the highest grade nickel-chrome resistance wire will not age or oxidize, thus assuring longer heater life.

Heater Specifications:

Capacity Maximum Output (BTU/Hr) Max Temperature Output Maxi
Air Flow (CFM)
Voltage AMP Rating Overall
Dimensions
(L x W x H)
Weight
(lbs.)
20 kW 61,400 155° F 1,200 480V
3 Phase
24.06 44" x 24" x 27" 146

GET A QUOTE

THERMOCLAVE, LTM and PEACH are registered trademarks of On Site Manufacturing, Inc.