1-866-935-6764

Bed bug reporting by guests of hotels and motels is rising and you need a proven, safe, discreet and fast response!

kill bugs with heat in hotels

THERMOCLAVE Heater Packages are:

  • Cost Saving - heaters maintain a constant discharge air temperature resulting in reduced operating costs

  • Faster - constant discharge air temperature also results in shorter treatment times, 4 - 6 hour average for 200 - 300 square feet* (returns a room to service faster)

  • Easy - to set up and use

  • Discrete - fewer pieces of equipment to treat a defined space and often no need for cables to exit a room

Heat is a proven method for killing bed bugs. With THERMOCLAVE Heater Package, you can utilize your maintenance staff to execute heat treatments the moment a bed bug problem is identified. Maximum effectiveness can be achieved when heat treatments are combined with a preventative natural residual control program done in-house or offered by a Pest Control Professional.

We offer the standard packages described below but realize that each Hospitality Property has its unique needs. If what you see doesn't seem to match what you're looking for -- Call Us! We'll listen and work with you to put together the right equipment that meets your needs -- including your specific electrical access requirements.

* Treatment times vary depending on cubic footage, construction type, initial ambient temperature, and items contained in a space.

THERMOCLAVE LTM 9 Package

THERMOCLAVE LTM 9 Package

Ideal for treatment areas up to 300 sq. ft. - hotel rooms, motel rooms, dorm rooms, self-storage units, pods, and larger vehicles such as transit buses and larger panel trucks.

killing bed bugs with heaters
  • 1 - THERMOCLAVE LTM 9 Electric Heater

  • 1 - 50' 8/3 50A Extension Cable

  • 2 - 16" 3,000 CFM 120V Hi Temp Distribution Fans

  • 1 - Wireless Temperature Transmitter
  • Heat controlled by a solid state relay.
  • Thermal overload protection.
  • High-quality tube axial fan with ball bearings for lowest noise and longest life.
  • Corrosion resistant, galvanized steel enclosure.
  • Discharge air duct.
  • NEMA style 6 - 50P Plug.
  • Dual discharge air temperature 125° F / 155° F set point.
  • Built-in electronic temperature controller and sensor proportionally modulates the heating load to match the exact capacity required for energy efficient operation.
  • Temperature sensor controls the heater proportionally to maintain the pre-set air discharge temperature.
  • Open coil elements made of the highest grade nickel-chrome resistance wire will not age or oxidize, thus assuring longer heater life.

Heater Specifications:

Capacity Maximum Output (BTU/Hr) Maximum Temperature Output Maximum Air Flow (CFM) Voltage AMP Rating Overall Dimensions
(L x W x H)
Weight
(lbs.)
9 kW 30,717 155° F 300 208/240V
Single Phase*
37.5 28.5" x 15" x 16.75"
(incl. 1.75" handles)
54
bed bugs*Three Power Circuit model also available.

Fan Specifications:

Air Flow (CFM) Speed (RPM) Voltage Noise Level (dB) Dimensions
(L x W x H)
3,000 - 3,250 1,160 120V 50 21.3" x 20.7" x 18.1"

THERMOCLAVE LTM 9 Stand-alone

THERMOCLAVE LTM 9

Ideal for treatment areas up to 300 sq. ft. - hotel rooms, motel rooms, dorm rooms, self-storage units, pods, and larger vehicles such as transit buses and larger panel trucks.

  • Heat controlled by a solid state relay.LTM9 Heater kills bed bugs
  • Thermal overload protection.
  • High-quality tube axial fan with ball bearings for lowest noise and longest life.
  • Corrosion resistant, galvanized steel enclosure.
  • Discharge air duct.
  • NEMA style 6 - 50P Plug.
  • Dual discharge air temperature 125° F / 155° F set point.
  • Built-in electronic temperature controller and sensor proportionally modulates the heating load to match the exact capacity required for energy efficient operation.
  • Temperature sensor controls the heater proportionally to maintain the pre-set air discharge temperature.
  • Open coil elements made of the highest grade nickel-chrome resistance wire will not age or oxidize, thus assuring longer heater life.

Heater Specifications:

Capacity Maximum Output (BTU/Hr) Maximum Temperature Output Maximum Air Flow (CFM) Voltage AMP Rating Overall Dimensions
(L x W x H)
Weight
(lbs.)
9 kW 30,717 155° F 300 208/240V
Single Phase*
37.5 28.5" x 15" x 16.75"
(incl. 1.75" handles)
54
bed bugs*Three Power Circuit model also available.

THERMOCLAVE LTM 20

THERMOCLAVE LTM 20

Ideal for treatment areas up to 400 - 600 sq. ft. - residential spaces, small commercial spaces, larger hotel rooms and motel rooms.

    high heat kills bed bugs
  • Heat controlled by a solid state relay.
  • Thermal overload protection.
  • High quality tube axial fan with ball bearings for lowest noise and longest life.
  • Corrosion resistant galvanized steel enclosure.
  • 50 amp twist lock electrical connection.
  • Dual discharge air temperature 125° F / 155° F set point.
  • Built-in electronic temperature controller and sensor proportionally modulates the heating load to match the exact capacity required for energy efficient operation.
  • Temperature sensor controls the heater proportionally to maintain the pre-set air discharge temperature.
  • Open coil elements made of the highest grade nickel-chrome resistance wire will not age or oxidize, thus assuring longer heater life.

Heater Specifications:

Capacity Maximum Output (BTU/Hr) Maximum Temperature Output Maximum Air Flow (CFM) Voltage AMP Rating Overall Dimensions
(L x W x H)
Weight
(lbs.)
20 kW 61,400 155° F 1,200 480V
3 Phase
24.06 44" x 24" x 27" 146